The Thermo Scientific UltiMate 3000 Standard LC system is the optimum choice HPLC from unsurpassed versatility, unmatched performance, superior reliability and ease of use
The Thermo Scientific UltiMate 3000 standard system fully supports conventional methods while offering compatibility with UHPLC applications. The reliable and durable UltiMate 3000 standard system with their perfect interplay of industry-leading technology, rigorous quality assurance, and predictive performance monitoring can be perfectly configured to meet your demands.
System specifications:
Category
|
UltiMate 3000 Standard LC
|
System pressure, maximum |
620 bar
|
Flow range, maximum |
0 - 10 mL/min
|
Pump options (default gradient delay volume) |
Binary (400 µL) Quaternary (690 µL) |
Biocompatibility |
No
|
System design |
Modular
|
Customizable gradient delay volume |
Yes
|
Injection volume range |
Standard: 0.01 - 100 µL Optional: 0.2 - 25 µL, 1.5 - 250 µL, 1.5 - 500 µL |
Sample cooling |
4 - 45°C
|
Sample capacity (standard) |
3 racks of 40 vials (2 mL) each, other rack formats available + capacity of 15 vials (10 mL) in the carousel |
Column compartment thermostatting |
Yes, 5 - 80°C
|
Detector choices |
Diode Array Detector Multiple Wavelength Detector Variable Wavelength Detector Charged Aerosol Detector Fluorescence Detector Refractive Index Detector Mass Spectrometer |
The Thermo Scientific UltiMate 3000 standard system fully supports conventional methods while offering compatibility with UHPLC applications. The reliable and durable UltiMate 3000 standard system with their perfect interplay of industry-leading technology, rigorous quality assurance, and predictive performance monitoring can be perfectly configured to meet your demands.
System specifications:
Category
|
UltiMate 3000 Standard LC
|
System pressure, maximum |
620 bar
|
Flow range, maximum |
0 - 10 mL/min
|
Pump options (default gradient delay volume) |
Binary (400 µL) Quaternary (690 µL) |
Biocompatibility |
No
|
System design |
Modular
|
Customizable gradient delay volume |
Yes
|
Injection volume range |
Standard: 0.01 - 100 µL Optional: 0.2 - 25 µL, 1.5 - 250 µL, 1.5 - 500 µL |
Sample cooling |
4 - 45°C
|
Sample capacity (standard) |
3 racks of 40 vials (2 mL) each, other rack formats available + capacity of 15 vials (10 mL) in the carousel |
Column compartment thermostatting |
Yes, 5 - 80°C
|
Detector choices |
Diode Array Detector Multiple Wavelength Detector Variable Wavelength Detector Charged Aerosol Detector Fluorescence Detector Refractive Index Detector Mass Spectrometer |