The particle size analyzer Anton Paar Litesizer 100 can determine the particle size and transmittance on a wide variety of samples
With the Anton Paar Litesizer 100 you can determine the particle size and transmittance on a wide variety of samples. It gives you rapid and accurate insight into your particle systems, and provides the tools for optimizing them by revealing how they change with time, pH, temperature and concentration.
• Particle size measurements from the nano- to the micrometer range.
• DLS backscatter detection ensures broad concentration range.
• Automatic measurement modes.
• Continuous transmittance measurement.
System specifications:
Category | Particle size analyzer Litesizer 100 |
Technical specifications | |
Light source |
Semiconductor laser diode 40 mW, 658 nm |
Temperature control range | 0 °C to 90 °C |
Standard accuracy | ±0.3 °C |
Laser warm-up time | 6 min |
Dimensions (W, D, H) | 460 mm, 485 mm, 135 mm |
Weight | approx. 16.3 kg |
Particle size | |
Measurement principle | Dynamic Light Scattering (DLS) |
Measuring range | 0.3 nm to 10 μm (particle diameter) |
Min. sample volume | 12 µL |
Min. concentration | 0.1 mg/mL (lysozyme) |
Max. concentration | 50 %w/v (sample-dependent) |
Accuracy | Better than ±2 % on NIST traceable standards |
Repeatability | Better than ±2 % on NIST traceable standards |
Measurement angle | 175 ° |
Transmittance | |
Measuring range | 0 % to 100 % |
Measuring time | 10 s |
Min. sample volume | 15 µL |
Accuracy | Better than ±1 % |
With the Anton Paar Litesizer 100 you can determine the particle size and transmittance on a wide variety of samples. It gives you rapid and accurate insight into your particle systems, and provides the tools for optimizing them by revealing how they change with time, pH, temperature and concentration.
• Particle size measurements from the nano- to the micrometer range.
• DLS backscatter detection ensures broad concentration range.
• Automatic measurement modes.
• Continuous transmittance measurement.
System specifications:
Category | Particle size analyzer Litesizer 100 |
Technical specifications | |
Light source |
Semiconductor laser diode 40 mW, 658 nm |
Temperature control range | 0 °C to 90 °C |
Standard accuracy | ±0.3 °C |
Laser warm-up time | 6 min |
Dimensions (W, D, H) | 460 mm, 485 mm, 135 mm |
Weight | approx. 16.3 kg |
Particle size | |
Measurement principle | Dynamic Light Scattering (DLS) |
Measuring range | 0.3 nm to 10 μm (particle diameter) |
Min. sample volume | 12 µL |
Min. concentration | 0.1 mg/mL (lysozyme) |
Max. concentration | 50 %w/v (sample-dependent) |
Accuracy | Better than ±2 % on NIST traceable standards |
Repeatability | Better than ±2 % on NIST traceable standards |
Measurement angle | 175 ° |
Transmittance | |
Measuring range | 0 % to 100 % |
Measuring time | 10 s |
Min. sample volume | 15 µL |
Accuracy | Better than ±1 % |