The Thermo Scientific UltiMate 3000 Rapid Separation LC systems accelerate HPLC for unrivaled performance and flexibility
Engineered to the highest level of performance, the Thermo Scientific UltiMate 3000 Rapid Separation (RS) system delivers the key flow rate and pressure capabilities to meet all LC challenges. With its extensive flow-pressure footprint, short sampler cycle times, high column temperatures, ultrafast data collection and processing, and high-resolution columns, the UltiMate 3000 RS system maximizes LC flexibility. This combination of features delivers optimal separations at ultrahigh speed while maintaining good resolution.
System specifications:
Category
|
UltiMate 3000 RS LC System
|
System pressure, maximum |
1000 bar
|
Flow range, maximum |
0 - 8 mL/min
|
Pump options (default gradient delay volume) |
Binary (200 µL) Quaternary (690 µL) |
Biocompatibility |
Yes
|
System design |
Modular
|
Customizable gradient delay volume |
Yes
|
Sample cooling |
4 - 45°C
|
Sample capacity (standard) |
3 racks of 40 vials (2 mL) each, other rack formats available + capacity of 15 vials (10 mL) in the carousel |
Column compartment thermostatting |
Yes, 5 - 110°C
|
Mobile phase pre-heater |
Yes
|
Post-column cooler eluate |
Yes
|
Detector choices |
Diode Array Detector Multiple Wavelength Detector Variable Wavelength Detector Charged Aerosol Detector Fluorescence Detector Refractive Index Detector Mass Spectrometer |
Engineered to the highest level of performance, the Thermo Scientific UltiMate 3000 Rapid Separation (RS) system delivers the key flow rate and pressure capabilities to meet all LC challenges. With its extensive flow-pressure footprint, short sampler cycle times, high column temperatures, ultrafast data collection and processing, and high-resolution columns, the UltiMate 3000 RS system maximizes LC flexibility. This combination of features delivers optimal separations at ultrahigh speed while maintaining good resolution.
System specifications:
Category
|
UltiMate 3000 RS LC System
|
System pressure, maximum |
1000 bar
|
Flow range, maximum |
0 - 8 mL/min
|
Pump options (default gradient delay volume) |
Binary (200 µL) Quaternary (690 µL) |
Biocompatibility |
Yes
|
System design |
Modular
|
Customizable gradient delay volume |
Yes
|
Sample cooling |
4 - 45°C
|
Sample capacity (standard) |
3 racks of 40 vials (2 mL) each, other rack formats available + capacity of 15 vials (10 mL) in the carousel |
Column compartment thermostatting |
Yes, 5 - 110°C
|
Mobile phase pre-heater |
Yes
|
Post-column cooler eluate |
Yes
|
Detector choices |
Diode Array Detector Multiple Wavelength Detector Variable Wavelength Detector Charged Aerosol Detector Fluorescence Detector Refractive Index Detector Mass Spectrometer |